Home/Checklists/Stair access tower
Stair access tower: inspection checklist
A stair tower giving access to the working levels. 20 checks in total.
Inspection record
- Scaffold tag no.
- Location / area
- Inspected by
- Date
- Next inspection due
Checks for this type
- 1Stair units complete and securedAll connections locked; no missing treads
- 2Handrails on both sides of each flightGuardrails and toe boards at every landing
- 3Landings fully boarded and clearNo materials or trip hazards on the landings
- 4Stair tower tied or braced as designedTies or bracing per the manufacturer's manual or design
Foundations
- 5Ground firm and level; base plates on sole boardsNo undermining, soft spots or water pooling
- 6Standards plumb; joints staggeredNo two adjacent joints in the same lift
Structure
- 7Ledgers level; joints staggeredJoints made with sleeve couplers or as designed
- 8Transoms at every standard and at spacing for the boardCheck board span for the thickness used
- 9Façade and ledger bracing completeAs TG20 compliance sheet or design
- 10Ties in place to the tie patternNone removed or altered without approval
- 11Couplers tight and correct typeRight-angle or swivel for load-bearing; none missing
Working platform
- 12Fully boarded; boards soundNo gaps, splits, rot or trip hazards; overhang 50 mm to 4 × thickness
- 13Guardrails completeMain rail ≥ 950 mm; gap between rails ≤ 470 mm
- 14Toe boards fitted and secure≥ 150 mm; brick guards or netting where materials are stored
- 15Not overloadedMaterials within the load class on the tag
Access
- 16Ladder secured at the right angleAbout 75°, extends ≈ 1 m above the landing
- 17Access openings protectedSelf-closing gate or equivalent; no climbing the frame
Site & records
- 18Clear of hazardsOverhead power lines, hot surfaces, live lines, traffic as per permit
- 19Tag fitted at every access pointStatus and load class match the register
- 20Design or compliance sheet availableFor any configuration outside standard guidance
Any “No” means the scaffold is not handed over: red tag it, fix it, then inspect again.
Based on TG20:21, TG30, SG35-style inspection practice, BS EN 12811-1 and the Saudi Aramco Construction Safety Manual. Not endorsed by any of them. Verify against the latest edition and the scaffold’s own design.
AL-YASSIN · alyassinscaffold.com/checklists/stair-access-scaffold/ · Check the latest editions and the scaffold design.
Do it on your phone
The same checks in the free field app, with photos, the tag status and a PDF report. In the app, pick scaffold type: Stair access.
Open in the free app